Typical Specification
On/Off sprin
g
return damper actuators shall be direct coupled type which require
no crank arm and linka
g
e and be capable o
f
direct mountin
g
to a
j
acksha
f
t up to a
1.05” diameter. The actuators must be designed so that they may be used
f
or either
clockwise or counterclockwise
f
ail-sa
f
e operation. Actuators shall be protected
from overload at all an
g
les of rotation. If required, two SPDT auxiliary switch shall
be provided havin
g
the capability o
f
one bein
g
ad
j
ustable. Actuators with auxiliary
switches must be constructed to meet the re
q
uirements
f
or Double Insulation so
a
n e
l
ectr
i
ca
l
groun
d
i
s not requ
i
re
d
to meet agency
li
st
i
ngs.
A
ctuators s
h
a
ll
b
e
cULus approved and have a 5 year warranty, and be manufactured under I
SO
9001
International Qualit
y
Control Standards. Actuators shall be as manufactured b
y
Belimo.
Wiring Diagrams
1
P
rovide overload protection and disconnect as required
.
2
C
A
U
TI
ON
Equipment Damage!
A
ctuators may be connected in parallel
.
P
ower consumption and input impedance must be observed.
3
N
o ground connection is required
.
4
F
or end position indication, interlock control, fan startup, etc.,
A
FBUP-
S
-X1 and AFXUP-
S
-X1 incorporates two built-in auxiliary switches:
2
x SPDT, 3A
(
0.5A
)
@250 VAC, UL Approved, one switch is fi xed at +10°,
o
ne
i
s a
dj
usta
bl
e 10° to 90°
.
M
eets cULus requirements without the need of an electrical
g
round con
-
n
ect
i
on.
WARNING
Live Electrical Components!
G
Durin
g
installation, testin
g
, servicin
g
and troubleshootin
g
of this product, it may be
necessar
y
to work with live electrical com
p
onents. Have a
q
ualifi ed licensed electrician or other
individual who has been properly trained in handling live electrical components per
f
orm these
tasks. Failure to
f
ollow all electrical sa
f
ety precautions when exposed to live electrical compo
-
nents could result in death or serious injury
.
AFBUP, AFBUP-S
AFXUP, AFBUP-S
W066_AFB
(
X
)
UP
On/Off wiring for AFBUP-X1, AFXUP-X
1
Wht
Blk
AFBUP-S
AFXUP-S
W067_AFB
(
X
)
UP-
S
Auxiliar
y
Switches for AFBUP-S-X1, AFXUP-S-X
1
Dimensions with 3-Way Valve
10
10
D
AB
C
Dimensions
(
Inches
)
Fail Safe
(
psi
)
Valve Siz
e
A
B
C
D
(Max) BHC
A
F
2
*AF
F7
50
HD 2” 4.
50
6
.1
5
6
.1
5
1
5
.
50
4
.7
5
200
F
75
0HDU
2”
4
.5
0
6
.
1
5
6
.
1
5
1
5.5
0
4
.75 5
0
F7
65
HD 2½”
5
.
00
6
.7
6
6
.7
6
1
6
.
00
5
.
50
200
F765HD
U
2½” 5.00 6.76 6.76 16.00 5.50
50
F780HD
U
3” 5.50 7.28 7.28 16.25 6.00
50
F750VI
C
2” 4.50 6.85 6.85 15.00 - 5
0
F750VI
C
2” 4.50 6.85 6.85 15.00
-
2
00
F765VI
C
2½” 5.00 7.46 7.46 15.50
-
50
A
FBUP
(
-S
)
-X1, AFXUP
(
-S
)
-X1 Actuators, On/Off
O
50904 - 02/12 -
S
ubject to change.
©
Belimo Aircontrols
(
U
S
A
)
, Inc.
Page view 11
1 2 ... 7 8 9 10 11 12 13 14 15 16 17 ... 41 42

Comments to this Manuals

No comments